SIRIUS (domestic) 3RV6/3RV5 circuit breaker

3RV6/3RV5 circuit breakers are compact current-limiting motor starting circuit breakers, which can be used for switching and protection of three-phase induction motors (power up to 45KW at AC 400V) and other loads (rated current up to 100A).

Product number:

3RV6/3RV5

Product consultation:

Product Description

SIRIUS (domestic) 3RV6/3RV5 circuit breaker


  3RV6/3RV5 circuit breakers are compact current-limiting motor starting circuit breakers, which can be used for switching and protection of three-phase induction motors (power up to 45KW at AC 400V) and other loads (rated current up to 100A).

Specification Notes:

3rv6/3rv5 circuit breaker includes 4 specifications:

Ls00 specification - 45mm wide

Rated current 16A

Applicable to induction motor 7.5kW at AC 400V

LS0 specification - 45mm wide

Rated current 40A

Applicable to induction motor 18.5kw at AC 400V

Ls2 specification - 55mm wide

Rated current 50A

Applicable to induction motor 25kW at AC 400V

LS3 specification - 75mm wide

Rated current 100A

Applicable to induction motor 45KW at AC 400V

 

 


Application:

Operating Conditions

3RV6/3RV5 circuit breakers are applicable to various climates and are used in the normal operating environment of enclosed spaces (such as no dust, corrosive gas or harmful gas). When installed in dusty and humid places, it is necessary to assemble a suitable shield.

3rv6/3rv5 circuit breakers can be wired from the top or bottom.

For the allowable ambient temperature, breaking capacity, tripping action current and other conditions of the circuit breaker, refer to the specific technical data and tripping curve in this chapter.

3rv6/3rv5 circuit breakers can be used in it system (IT network), but different short-circuit breaking capacities in it system should be considered.

Even for motors with the same rated power, their working current, starting current and peak current are different due to the instantaneous peak current. Therefore, the motor rating in the selection table can only represent the guidance data, and the actual rating data and starting data of the motor are important for selecting the appropriate circuit breaker. This principle also applies to circuit breakers for transformer protection.


Application Category:

3rv6/3rv5 circuit breakers can be used for:

L motor protection

L system protection

L starter combined short circuit protection

L transformer protection

L as main switch and emergency stop switch

It system (IT network)

L DC circuit

L Explosion-proof application (ATEX)

Related Products